Multi-Leg Wire Rope Slings

2 and 3 Leg Wire Rope Slings
| ROPE DIAMETER IN INCHES | RATED CAPACITY IN TONS 60° | RATED CAPACITY IN TONS 45° | RATED CAPACITY IN TONS 30° | LINK![]() | RATED CAPACITY IN TONS 60° | RATED CAPACITY IN TONS 45° | RATED CAPACITY IN TONS 30° | LINK![]() | HOOK SIZE IN TON |
|---|---|---|---|---|---|---|---|---|---|
| 1/4” | 1.1 | .91 | .65 | 1/2 CP | 1.7 | 1.4 | .97 | 5/8 CP | 1 |
| 5/16” | 1.7 | 1.4 | 1 | 5/8 CP | 2.6 | 2.1 | 1.5 | 3/4 CP | 1 |
| 3/8” | 2.5 | 2 | 1.4 | 3/4 CP | 3.7 | 3 | 2.2 | 3/4 CP | 1 1/2 |
| 1/2” | 4.4 | 3.6 | 2.5 | 1 CP | 6.6 | 5.4 | 3.8 | 1 OB | 3 |
| 9/16” | 5.5 | 4.5 | 3.2 | 1 OB | 8.3 | 6.8 | 4.8 | 1 OB | 4 1/2 |
| 5/8” | 6.8 | 5.5 | 3.9 | 1 1/4 CP | 10 | 8.3 | 5.9 | 1 OB | 4 1/2 |
| 3/4” | 9.7 | 7.9 | 5.6 | 1 OB | 15 | 12 | 8.4 | 1 1/4 OB | 7 |
| 7/8” | 13 | 11 | 7.6 | 1 1/4 OB | 20 | 16 | 11 | 1 1/2 OB | 11 |
| 1” | 17 | 14 | 9.8 | 1 1/2 OB | 26 | 21 | 15 | 1 3/4 OB | 11 |
| 1 1/8” | 21 | 17 | 12 | 1 1/2 OB | 31 | 26 | 18 | 2 OB | 15 |
| 1 1/4” | 26 | 21 | 15 | 1 3/4 OB | 38 | 31 | 22 | 2 OB | 15 |
| 1 3/8” | 31 | 25 | 18 | 1 3/4 OB | 46 | 38 | 27 | 2 1/4 OB | 22 |
| 1 1/2” | 37 | 30 | 21 | 2 OB | 55 | 45 | 32 | 2 1/2 OB | 22 |
4 Leg Wire Rope Slings
| ROPE DIAMETER IN INCHES | RATED CAPACITY IN TONS 60° | RATED CAPACITY IN TONS 45° | RATED CAPACITY IN TONS 30° | LINK![]() | HOOK SIZE IN TON |
|---|---|---|---|---|---|
| 1/4” | 2.2 | 1.8 | 1.3 | 3/4 CP | 1 |
| 5/16” | 3.5 | 2.8 | 2 | 7/8 CP | 1 |
| 3/8” | 5 | 4.1 | 2.9 | 1 CP | 1 1/2 |
| 1/2” | 8.8 | 7.1 | 5.1 | 1 1/4 CP | 3 |
| 9/16” | 11 | 9 | 6.4 | 1 OB | 4 1/2 |
| 5/8” | 14 | 11 | 7.8 | 1 1/4 OB | 4 1/2 |
| 3/4” | 19 | 16 | 11 | 1 1/2 OB | 7 |
| 7/8” | 26 | 21 | 15 | 1 3/4 OB | 11 |
| 1” | 34 | 28 | 20 | 2 OB | 11 |
| 1 1/8” | 42 | 34 | 24 | 2 1/4 OB | 15 |
| 1 1/4” | 51 | 42 | 30 | 2 1/4 OB | 15 |
| 1 3/8” | 62 | 50 | 36 | 2 1/2 OB | 22 |
| 1 1/2” | 73 | 60 | 42 | 2 3/4 OB | 22 |
Warning!
Work load limits will be reduced when less than 90 ° from horizontal. (See Efficiency Chart) Angles of less than 30 ° are not to be used. Inspect before use. Additional requirements and safe operating practices are outlined in current OSHA, Federal Register Part 29, 1910.184 and ASME B30.9 c-2006. Death or injury can occur from improper use or maintenance!